HOME > Products > MVE Variō 1800
MVE Variō 1800 Series

The MVE VariōTM Series is the new innovative and energy efficient alternative for ultra low temperature to cryogenic storage. The completely dry sample storage area will maintain a user-defined temperature anywhere between -50°C and -150°C.
The MVE Variō Series significantly reduces the possibility of sample contamination via contact with LN2 while providing the safety margin and consistent temperature profile, even with the lid open, that is associated with LN2 based cryogenic storage. The MVE Variō Series is able to provide all of this with less than 1% of the power consumption and approximately 70% overall operating cost savings when compared to the leading mechanical freezers.

Features Include
  • ●Completely dry storage area
  • ●Consistent temperature profile, even with lid open
  • ●Improved processing time, minimal increase in temperature
     when warm samples introduced
  • ●No thermal load; no heat introduced into room
     and no additional HVAC required
  • ≫Product Guide(PDF)

Temperature Test

click to enlarge

* Temp Test indicates typical performance of MVE Variō 1800 freezer with full inventory system and factory recommended settings. Actual performance may vary with atmospheric conditions and usage.

Rack layouts

click to enlarge

Products Specification
MVE Variō 1879P MVE Variō 1881R MVE Variō 1894R
Maximum Storage Capacity
1.2 & 2 ml Vials (Internally Threaded) 79950 81900 94500
Number of Racks 100 cell boxes 54 60 60
Number of Racks 25 cell boxes 30 12 12
Number of Stages per Rack 13 13 15
Performance
Temperature Range -20°C, -150°C -20°C, -150°C -20°C, -150°C
LN2 Usage at -80℃ L/day 12 12 15
Power consumption (cont.)W 8 8 8
Unit Dimensions
Neck Opening in. (mm) 25.0 (635) 25.0 (635) 25.0 (635)
Usable Internal Height in. (mm) 29.5 (749) 29.2 (741) 34.2 (868)
Inner Diameter in. (mm) 56.0 (1422) 54.8 (1391) 54.8 (1391)
Overall Height in. (mm) 62.1 (1577) 61.3 (1556) 66.3 (1683)
Door Width Requirement* in. (mm) 60.0 (1524) 60.0 (1524) 60.0 (1524)
Weight Empty lb. (kg) 1606 (728) 1721 (781) 1721 (781)
Blood Bag Capacities
Total Bags Bags/
Frame
No.
Frames
Total Bags Bags/
Frame
No.
Frames
Total Bags Bags/
Frame
No.
Frames
791 OS/U
(25 ml)
5866 7 838 5628 7 804 6432 8 804
Compact
(25ml)
8622 9 958 9414 9 1046 11506 11 1046
4R9951
(50 ml)
2952 6 492 2940 6 490 3920 8 490
4R9953
(250 ml)
1584 4 396 1608 4 402 2010 5 402
4R9955
(500 ml)
1104 4 276 1240 4 310 1550 5 310
DF200
(200 ml)
960 4 240 984 4 246 1230 5 246
DF700
(700 ml)
504 4 126 544 4 136 680 5 136

* Minimum width required for vessel to pass through opening. Footprint may vary. Contact Tech
Service for detailed drawings.

products
MVE Vario 1800 Series

The MVE VariōTM Series is the new innovative and energy efficient alternative for ultra low temperature to cryogenic storage. The completely dry sample storage area will maintain a user-defined temperature anywhere between -50°C and -150°C.
The MVE Variō Series significantly reduces the possibility of sample contamination via contact with LN2 while providing the safety margin and consistent temperature profile, even with the lid open, that is associated with LN2 based cryogenic storage. The MVE Variō Series is able to provide all of this with less than 1% of the power consumption and approximately 70% overall operating cost savings when compared to the leading mechanical freezers.

feature
  • ●Completely dry storage area
  • ●Consistent temperature profile, even with lid open
  • ●Improved processing time, minimal increase in temperature when warm samples introduced
  • ●No thermal load; no heat introduced into room and no additional HVAC required

≫Product Guide(PDF)

rack layout
Vario 1800 rack layout
Vario 1800 rack layout
Products Specification
MVE Variō 1879P MVE Variō 1881R MVE Variō 1894R
Maximum Storage Capacity
1.2 & 2 ml Vials (Internally Threaded)
79950 81900 94500
Number of Racks 100 cell boxes
54 60 60
Number of Racks 25 cell boxes
30 12 12
Number of Stages per Rack
13 13 15
Performance
Temperature Range
-20℃, -150℃ -20℃, -150℃ -20℃, -150℃
LN2 Usage at -80℃ L/day
12 12 15
Power consumption (cont.)W
8 8 8
Unit Dimensions
Neck Opening in. (mm)
25.0 (635) 25.0 (635) 25.0 (635)
Usable Internal Height in. (mm)
29.5 (749) 29.2 (741) 34.2 (868)
Inner Diameter in. (mm)
56.0 (1422) 54.8 (1391) 54.8 (1391)
Overall Height in. (mm)
62.1 (1577) 61.3 (1556) 66.3 (1683)
Door Width Requirement* in. (mm)
60.0 (1524) 60.0 (1524) 60.0 (1524)
Weight Empty lb. (kg)
1606 (728) 1721 (781) 1721 (781)
Blood Bag Capacities
Total Bags(top)
Bags/Frame(mid)
No. Frames(lower)
791 OS/U (25 ml)
5866
7
838
5628
7
804
6432
8
804
Compact(25ml)
8622
9
958
9414
9
1046
11506
11
1046
4R9951 (50 ml)
2952
6
492
2940
6
490
3920
8
490
4R9953 (250 ml)
1584
4
396
1608
4
402
2010
5
402
4R9955 (500 ml)
1104
4
276
1240
4
310
1550
5
310
DF200 (200 ml)
960
4
240
984
4
246
1230
5
246
DF700 (700 ml)
504
4
126
544
4
136
680
5
136

* Minimum width required for vessel to pass through opening. Footprint may vary. Contact Tech Service for detailed drawings.